DPC
II Plus and EZ Welder System Users Manual
MPC Probe
The cable connection diagram for connecting the
MultiProbe Controller module is shown in Sec-
tion 3 in Figure 36. The flow chart for the Pro-
cess Control menu with a MultiProbe Controller
installed is shown in Figure 712. If you do not
have a Power Output module installed, the Energy
Weld Method menu will not be displayed.
The MultiProbe Controller (MPC) flow chart
adds three options to the basic Hand Probe flow
chart shown in Figure 77.
1. An AUTO STOP option is included which can
be enabled or disabled.
2. A delay time value (T
delay
) can be entered for
untimed operation.
3. A weld method called GROUND DETECT is now
available. This method requires values to be
entered for the maximum weld time (T
max
) and
for a parameter called scrub time (T
scrub
).
AUTO
*
STOP Option
This menu is shown in Figure 713. To use this
option, move the SH704 jumper block to JU715
(see Figure 512). Use the down arrow key to se-
lect ENABLE and press ENTER to continue.
When Auto Stop is enabled, a signal on pin 9 of the
HD15 SYSTEM IN connector will be recognized.
This permits external automation equipment to stop
the welding cycle. If Auto Stop is set to disable, then
the signal will be ignored. If the SH704 jumper block
is left in the EndOfWeld factory default position
(JU716), only the welding is stopped. Any pro-
grammed Hold or Afterburst (discussed later) will
still be executed regardless of the Auto Stop mode.
AUTO STOP
DISABLE
ENABLE
UNTIMED MPC PROBE
ENABLE or DISABLE
AUTO STOP
TIMED
MPC
PROBE
UNTIMED
MPC
PROBE
WELD METHOD
TIME ENERGY
GND.
DETECT
TRIGGER METHOD
TIMED MPC PROBE
RTW
RTW
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
T
weld
E
weld
T
max
T
max
T
scrub
T
delay
T
weld
RTW
= Ready To Weld
LEGEND
= Front Panel ENTER Key
(Section 4.3 Menu Keys)
ENTER
= Parameter Value Entry
T = Time
E = Energy
Maximum
E
weld
Minimum
E
weld
= 12,000 Joules
= 1 Joule*
Maximum
T
max
Minimum
T
max
= 30.000 Seconds
= 0.001 Second*
Maximum
T
weld
Minimum
T
weld
= 30.000 Seconds
= 0.001 Second*
Maximum
T
delay
Minimum
T
delay
= 30.000 Seconds
= 0.000 Second
Maximum
T
scrub
Minimum
T
scrub
= 0.150 Seconds
= 0.001 Second
* These values can be set to zero, but will not produce any
output. The values listed represent the resolution and are
the smallest values that will produce any output signal.
Figure 712 MultiProbe Controller Flow Chart
Figure 713 MPC Probe Auto Stop Mode Menu
* AUTO refers to Automation not automatic