Dukane DPC II Plus Manuel d'utilisateur Page 42

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 190
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 41
32
Dukane Manual Part No. 40356601
DPC
II Plus and EZ Welder System Users Manual
System Power Output Display
The tricolor System Power Output Display indi-
cates the percentage of ultrasonic power being
drawn by the load.
Green Eight green vertical bars indicating
10% to 80% power output are dis-
played during normal operation. Fig-
ure 4-5 shows the display indicating
80% output power.
Yellow Two yellow bars for 90% and 100%
power output warn that the genera-
tor is operating near its maximum
rated output.
Red The last red bar indicates that the
generator is in an overload condition
delivering more than its rated out-
put power. Figure 4-6 shows the red
overload and two yellow warning in-
dicators. The red warning indicator
lights up just prior to an overload
condition. The ultrasonic signal is
shut down when an overload condi-
tion occurs.
GREEN
YELLOW
RED
Figure 46 Warning Indicators
Figure 45 Normal Operation
NOTE
The available output power is directly propor-
tional to the Amplitude setting.
Example: A 2200 Watt rated DPC set to 80%
Amplitude will overload at 1760 Watts.
(2200W
x
0.80 = 1760 Watts)